Shrnutí obsahu

Strany 1 - Marley MH

Marley MHFLUID COOLERENGINEERING DATA AND SPECIFICATIONS

Strany 2 - Table of Contents

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 103.0 Performance Warranty: 3.1 CTI Certification notwithstanding, the fluid

Strany 3 - MH Fluid Cooler

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 116.0 Construction: 6.1 Except where otherwise specified, all components of

Strany 4 - Engineering Data: Schematic

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 12blades attached to galvanized steel hubs with U-bolts. Blades shall be indiv

Strany 5

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 138.2 Coil air-inlet louvers shall be a minimum of 0'-5" air travel

Strany 6 - Engineering Data: Support

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 1411.0 Access: 11.1 A large galvanized steel, rectangular access door shall

Strany 7

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 15 Stainless Steel Options All Stainless Steel Fluid Cooler:1.1: Replace

Strany 8

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 16 Stainless Steel Distribution Basin:9.1 Replace paragraph 9.1 with the

Strany 9

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 17ing. The guardrail assembly shall be hot dipped galvanized after welding

Strany 10 - Specifications: Base

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 18 Ladder Safety Gate:11.3 Add the following paragraph in the Access sec

Strany 11

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 19 Control Options Combination Fan and Pump Motor Starter Control Panel:

Strany 12

Engineering DataSchematic – Single-Flow Models ____________________________________________________ 4Schematic – Double-Flow Models __________________

Strany 13

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 20selector switch shall be provided. Dry status contacts wired to user term

Strany 14

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 21 Water Level Control System: 11.2 Add the following paragraph in the C

Strany 15 - Specifications: Options

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 22cold-water temperature. As an option to receiving the speed reference sig

Strany 16

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 23shall be provided for voltage isolation dur-ing VFD maintenance. An integ

Strany 17

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 24 Miscellaneous Options Positive Closure Dampers: 4.2 Add the followin

Strany 18

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 25 Air Inlet Screens: 8.4 Add the following paragraph: The air inlet fac

Strany 19

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 26 Sound Control: 1.2 Add the following paragraph in the Base section: Th

Strany 20

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Options 27requires no oil changes for the first five (5) years of operation. The ge

Strany 21

Marley MH fluid coolerENGINEERING DATA AND SPECIFICATIONSSPX COOLING TECHNOLOGIES, INC.7401 WEST 129 STREETOVERLAND PARK, KANSAS 66213 USAP: 913 664 7

Strany 22

The Marley MH Fluid Cooler is one of the most efficient closed-circuit heat rejection products on the market—and your best choice for industrial and H

Strany 23

MH Fluid Cooler — Engineering Data: Schematic 4WLHINSTALLEDHEIGHTFLUID INACCESSDOOR2'-3" MAXPUMPFLUID OUTPLAN VIEWSIDE ELEVATION AIR INLET E

Strany 24

MH Fluid Cooler — Engineering Data: Schematic 5WLHINSTALLEDHEIGHTFLUID INACCESSDOORFLUID OUTPLAN VIEWSIDE ELEVATION AIR INLET ELEVATIONModelDimensions

Strany 25

MH Fluid Cooler — Engineering Data: Support 6D DDAIR INLETFAC EAIR INLETFAC EAIR INLETFAC ESINGLE-FLOW MODELS DOUBLE-FLOW MODELS 3 1/2" 3 1/2&qu

Strany 26

MH Fluid Cooler — Engineering Data: Freeze Prevention 7FLUID COOLER COILWhen the ambient temperature falls below 32°F, heat loss from the coil be subs

Strany 27

MH Fluid Cooler — Engineering Data: Water Quality 8SYSTEM CLEANLINESSThe MH Fluid Cooler can be a very effective air washer. Atmospheric dust able to

Strany 28 - fluid cooler

SpecificationsSpecification ValueMH Fluid Cooler — Specifications: Base 91.0 Base:1.1 Provide an induced-draft, crossflow-type, factory assembled, g